      Agree with request with the following modifications:

      Remove useContext: qualityprogram slice from publishable measure and publishable library.

      Leave Quality Program profile as is - no changes.

       

      Show
      Agree with request with the following modifications: Remove useContext: qualityprogram slice from publishable measure and publishable library. Leave Quality Program profile as is - no changes.  
    • Matt Tiller/ Bryn Rhodes: 20-0-0
    • Clarification
    • Non-substantive

    Description

      The value set Quality Programs is used in three QM profiles, listed below, specifically in slice useContext:qualityProgram. That slice should be relaxed to cardinality of 0..*, and the value set bound to useContext:qualityProgram.value[x] should be "example" (or possibly "preferred").

      The three profiles that are affected:

      Quality Program (note that in this profile, the Quality Program value set is already "example", so no change is needed to binding strength here)

      Publishable Measure

      Publishable Library

       