The following items include elements identified as Must Support and these have example value set bindings. Change the bindings to Preferred:
- QICoreServiceRequest
- ServiceRequest.reasonCode uses http://hl7.org/fhir/ValueSet/procedure-reason which is SNOMED condition codes - Change to "Preferred"
- ServiceRequest.bodySite uses http://hl7.org/fhir/ValueSet/body-site Change to "Preferred" Consider note to OO to consider update to more recent version of SNOMED
- QICoreServiceNotRequested
- ServiceRequest.bodySite uses http://hl7.org/fhir/ValueSet/body-site Change to "Preferred" Consider note to OO to consider update to more recent version of SNOMED