Uploaded image for project: 'FHIR Specification Feedback'
  1. FHIR Specification Feedback
  2. FHIR-34352

evaluatedResources in Summary MeasureReport should not be 0..0

    XMLWordPrintableJSON

Details

    • Icon: Change Request Change Request
    • Resolution: Persuasive
    • Icon: Medium Medium
    • US Da Vinci DEQM (FHIR)
    • current
    • Clinical Quality Information
    • DEQM Summary MeasureReport Profile
    • Hide

      Notes from 12/17/21 CQI meeting

      Remove the constraint of the evaluatedResource from 0..0 and update to 0..*

      For the use case of summary reports, the evaluatedResource element is used to communicate the result of intermediate calculations such as supplemental data. 

      Add an example.

       

       

      Notes from 12/10/2021 CQI meeting:

      Agree that evaluatedResource should be changed from 0..0 to 0..*

      Show
      Notes from 12/17/21 CQI meeting Remove the constraint of the evaluatedResource from 0..0 and update to 0..* For the use case of summary reports, the evaluatedResource element is used to communicate the result of intermediate calculations such as supplemental data.  Add an example.     Notes from 12/10/2021 CQI meeting: Agree that evaluatedResource should be changed from 0..0 to 0..*
    • Bryn Rhodes/ Rob Reynolds: 14-0-0
    • Correction
    • Compatible, substantive

    Description

      There may be a need to attach resources to a Summary MeasureReport.  The current constraint of 0..0 does not allow for that

       

      Note:  The need for this may change when SUpplemental Data element is added in FHIR R5

       

      Attachments

        Activity

          People

            bryn.rhodes Bryn Rhodes
            lmichaelsen Linda Michaelsen
            Watchers:
            3 Start watching this issue

            Dates

              Created:
              Updated:
              Resolved: