Uploaded image for project: 'FHIR Specification Feedback'
  1. FHIR Specification Feedback
  2. FHIR-12342

endpoint-connection-type values don't capture XDS/XCA correctly

    XMLWordPrintableJSON

    Details

    • Type: Change Request
    • Status: Resolved - change required (View Workflow)
    • Priority: Medium
    • Resolution: Persuasive with Modification
    • Specification:
      FHIR Core (FHIR)
    • Raised in Version:
      DSTU2
    • Work Group:
      Patient Administration
    • Related Artifact(s):
      EndPoint
    • Related Page(s):
      Terminologies - Valuesets
    • Resolution Description:
      Hide

      The cardinality of the Endpoint.connectionType will be updated from 1..1 to 1..*.

       

      Show
      The cardinality of the Endpoint.connectionType will be updated from 1..1 to 1..*.  
    • Resolution Vote:
      Brian Postlethwaite / Alex de Leon : 6-0-0
    • Change Category:
      Enhancement
    • Change Impact:
      Non-compatible

      Description

      XDS is not a single endpoint. There are typically 4 recipient endpoints: query (ITI-18), retrieve (ITI-43), publish documents (with metadata) (ITI-41), and publish metadata (ITI-42). (There are a couple of other transactions which may their own endpoints too.) I expect only the first two are relevant for FHIR.

      For XCA there are recipient endpoints for two transactions: query (ITI-38) and retrieve (ITI-39).

      There should probably be separate codes for each of these

        Attachments

          Activity

            People

            Assignee:
            Unassigned Unassigned
            Reporter:
            esilver Elliot Silver
            Watchers:
            5 Start watching this issue

              Dates

              Created:
              Updated:
              Resolved:
              Vote Date: