Uploaded image for project: 'V2 Specification Feedback'
  1. V2 Specification Feedback
  2. V2-25630

IN3-20: correct data type?

    XMLWordPrintableJSON

Details

    • Icon: Technical Correction Technical Correction
    • Resolution: Persuasive
    • Icon: Medium Medium
    • V2.x Message Specification (V2)
    • V2.9.1
    • V2 Mgmt Group
    • Insurance Additional Information, Certification (IN3)
    • Financial Management (Chapter 6)
    • 6.5.8
    • Hide

      The correct fix is to remove the table reference to HL70136, as that is defined in the ICD datatype and a table reference to a subcomponent of a datatype does not belong at the field level

      Show
      The correct fix is to remove the table reference to HL70136, as that is defined in the ICD datatype and a table reference to a subcomponent of a datatype does not belong at the field level
    • Correction
    • Non-substantive
    • V2.9.1

    Description

      For IN3-20, pre-certification requirement,  the data type ICD is specified, but table 0136 (yes/no) is assigned. What is correct?

      • make it data type ID with table 0136
      • remove table 0136 because it belongs to ICD.2

      Attachments

        Activity

          People

            Unassigned Unassigned
            FrankOemig Frank Oemig
            Watchers:
            1 Start watching this issue

            Dates

              Created:
              Updated:
              Resolved: