Uploaded image for project: 'FHIR Specification Feedback'
  1. FHIR Specification Feedback
  2. FHIR-45135

Fix invalid PlanDefinition opioid and low suicide risk examples

    XMLWordPrintableJSON

Details

    • Icon: Technical Correction Technical Correction
    • Resolution: Persuasive
    • Icon: Medium Medium
    • FHIR Core (FHIR)
    • R5
    • Clinical Decision Support
    • PlanDefinition
    • Hide

      Agreed, correct examples as suggested

      Show
      Agreed, correct examples as suggested
    • Correction
    • Non-substantive
    • Yes

    Description

      In the opioid examples the incorrect placement of the cqf-strengthOfRecommendation and cqf-qualityOfEvidence extensions outside of their defined context was causing the build to fail.  The extensions were moved directly under PlanDefinition.action.  The presence of the xsi:schemaLocation tag in the low suicide risk example also caused a validation issue, and it was removed.  The 'url' elements were also removed, as they are not needed for example instances and their presence with an HL7 url results in the "When HL7 is publishing a resource, the owning committee must be stated using the http://hl7.org/fhir/StructureDefinition/structuredefinition-wg extension" errors.

      Attachments

        Activity

          People

            Unassigned Unassigned
            rhausam Robert Hausam
            Watchers:
            1 Start watching this issue

            Dates

              Created:
              Updated:
              Resolved: