Uploaded image for project: 'FHIR Specification Feedback'
  1. FHIR Specification Feedback
  2. FHIR-45006

Terminology Services Closure Table concept map direction description is incorrect

    XMLWordPrintableJSON

Details

    • Icon: Change Request Change Request
    • Resolution: Persuasive
    • Icon: Medium Medium
    • FHIR Core (FHIR)
    • R5
    • Terminology Infrastructure
    • Terminology Module
    • 4.7.11 Maintaining a Closure Table
    • Hide

      Change this text:

      The equivalence is read from target to source (e.g. the target is 'wider' than the source).

      to:

      The relationship is read from source to target (e.g. source-is-narrower-than-target).

      Change this text:

      From the spec:

      to:

      From the definition for ConceptMap.group.element.target.relationship:   (leave the specific example)

      (include a link to that location in the change:  https://www.hl7.org/fhir/conceptmap-definitions.html#ConceptMap.group.element.target.relationship 

      Show
      Change this text: The equivalence is read from target to source (e.g. the target is 'wider' than the source). to: The relationship is read from source to target (e.g. source-is-narrower-than-target). Change this text: From the spec: to: From the definition for ConceptMap.group.element.target.relationship:   (leave the specific example) (include a link to that location in the change:   https://www.hl7.org/fhir/conceptmap-definitions.html#ConceptMap.group.element.target.relationship  
    • Reuben Daniels/Marc Duteau: 3-0-0
    • Clarification
    • Non-substantive

    Description

      In the notes for section, below examples https://www.hl7.org/fhir/terminology-service.html#closure-add there is a statement  (3rd bullet):

      • it's important to understand the relationship the right way around. From the spec: The equivalence is read from target to source (e.g. the target is 'wider' than the source). So in this case, 128599005 (Structural disorder of heart) subsumes 22298006 (Myocardial infarction)

      The "spec" should be clarified - is the reference to the HL7 FHIR Core specification - and to what part of the specification? Its not clear that this is a reference to language in ConceptMap or something else. 

       

       

      Attachments

        Activity

          People

            Unassigned Unassigned
            carmela_couderc Carmela A. Couderc
            Watchers:
            1 Start watching this issue

            Dates

              Created:
              Updated:
              Resolved: