Uploaded image for project: 'FHIR Specification Feedback'
  1. FHIR Specification Feedback
  2. FHIR-44334

Distinguish or remove observation-specimenCode extension

XMLWordPrintableJSON

    • Icon: Change Request Change Request
    • Resolution: Persuasive
    • Icon: Highest Highest
    • FHIR Extensions Pack (FHIR)
    • 1.0.0
    • Orders & Observations
    • (NA)
    • 200.1
    • Hide

      Given the ability to use the referenced Specimen resource to represent just a code, we will remove this extension. 

      Show
      Given the ability to use the referenced Specimen resource to represent just a code, we will remove this extension. 
    • Marti Velezis / Yanick Gaudet : 2-0-2
    • Enhancement
    • Non-compatible
    • 1.0.0

      Add description of when this extension should be used instead of Observation.specimen. A code-only specimen identification can be done with Observation.specimen.identifier or a contained (mostly-empty) specimen resource. If the use cannot be strongly articulated, remove this extension, or consider changing specimen to CodeableReference.

      (Comment 13 - imported by: Ron G. Parker)