Uploaded image for project: 'FHIR Specification Feedback'
  1. FHIR Specification Feedback
  2. FHIR-43713

Canonical tail of Measure should be the name

    XMLWordPrintableJSON

Details

    • Icon: Change Request Change Request
    • Resolution: Persuasive with Modification
    • Icon: Medium Medium
    • US Quality Measures (FHIR)
    • 5.0.0-ballot [deprecated]
    • Clinical Quality Information
    • QMs
    • Hide

      Agree with recommendation. 

      1. Will add conformance requirement to section 3.1:

      The tail (meaning everything after the last slash in the URL) of the canonical URL of the Measure resource SHALL match the name of the Measure. Note that special characters in measure names are restricted by the name element and will not impact the canonical URL of the measure resource.

      2. add invariant to CQFM Publishable Measure profile (considering CRMI refactoring) to enforce the conformance requirement in a computable way using FHIRPath

      Show
      Agree with recommendation.  1. Will add conformance requirement to section 3.1: The tail (meaning everything after the last slash in the URL) of the canonical URL of the Measure resource SHALL match the name of the Measure. Note that special characters in measure names are restricted by the name element and will not impact the canonical URL of the measure resource. 2. add invariant to CQFM Publishable Measure profile (considering CRMI refactoring) to enforce the conformance requirement in a computable way using FHIRPath
    • Jen Seeman/ Bryn Rhodes: 20-0-0
    • Enhancement
    • Non-compatible

    Description

      Add a conformance requirement that the tail of the canonical URL for a Measure SHALL be the same as the name of the Measure.

      Attachments

        Activity

          People

            abdullah.rafiqi@icf.com AbdullahRafiqi
            bryn.rhodes Bryn Rhodes
            Watchers:
            5 Start watching this issue

            Dates

              Created:
              Updated:
              Resolved: