Uploaded image for project: 'FHIR Specification Feedback'
  1. FHIR Specification Feedback
  2. FHIR-43642

Issues with risk adjustment Snippet 3-28

    XMLWordPrintableJSON

Details

    • Icon: Technical Correction Technical Correction
    • Resolution: Persuasive
    • Icon: Highest Highest

    Description

      A couple errors in the Snippet 3-28: Sample Risk Adjustment Variable. They need to be updated to match the source.

      1) The code should be risk-adjustment-factor not risk-adjustment-variable. 

      2) SupplementalData.identifier should be id not identifier and update the value of id to match the source file

       