Align scope of Laboratory Specialty

    XMLWordPrintableJSON

Details

    • Icon: Change Request Change Request
    • Resolution: Not Persuasive
    • Icon: Medium Medium
    • EU Laboratory Report (FHIR)
    • 0.1.0-ballot [deprecated]
    • HL7 Europe
    • Laboratory Specialty
    • Hide

      FHIR IG scope states: "This Implementation Guide applies to laboratory reports within the core fields of in-vitro diagnostics, for example clinical biochemistry, haematology, immunohematology, microbiology, immunology, while leaving out some specialised laboratory domains like histopathology or medical genetics."

      The intention was not to exclude those two specialties completely from structured  reporting according to this IG but to explain that this IG might not satisfy all reporting needs of those two laboratory specialties. In this sense specialty value set should also include these "excluded" specialties as they might report using structured results compliant with the IG specification.

      Show
      FHIR IG scope states: "This Implementation Guide applies to laboratory reports within the core fields of in-vitro diagnostics, for example clinical biochemistry, haematology, immunohematology, microbiology, immunology, while leaving out some specialised laboratory domains like histopathology or medical genetics." The intention was not to exclude those two specialties completely from structured  reporting according to this IG but to explain that this IG might not satisfy all reporting needs of those two laboratory specialties. In this sense specialty value set should also include these "excluded" specialties as they might report using structured results compliant with the IG specification.
    • Daniel Karlsson/Rob Hausam: 14-0-0

    Description

      In terms of content of the ValueSet, the differentiation of the laboratory specialty „pathology“ is predominant (5/8 Terms). This is not in alignment with the entity “Observation.code” where the LOINC class „pathology“ is excluded.

      One term of the ValueSet is „Genetic pathology“, which is in disagreement of the scope of the eHN lab result guideline, where genetics data have been explicitly excluded.

       
      “Laboratory Specialty” content should be aligned with the scope described in the eHN guideline, i.e. exclusion of specialised laboratory domains as histopathology and genetics.

      It should be further refined, which specialties are explicitly in scope or out of scope!