Uploaded image for project: 'FHIR Specification Feedback'
  1. FHIR Specification Feedback
  2. FHIR-43252

Specimen.processing.additive

    XMLWordPrintableJSON

Details

    • Icon: Change Request Change Request
    • Resolution: Not Persuasive
    • Icon: Medium Medium
    • EU Laboratory Report (FHIR)
    • 0.1.0-ballot [deprecated]
    • HL7 Europe
    • Substance: Specimen Additive Substance
    • Hide

      The binding is in any case of type preferred, so that this doesn't preclude the use of additional concepts.

      The revision of the value sets will be part of the regular artifacts maintenance

      Show
      The binding is in any case of type preferred, so that this doesn't preclude the use of additional concepts. The revision of the value sets will be part of the regular artifacts maintenance
    • Hynek Kruzik / Alexander Henket : 17-0-0

    Description

      This SNOMED-valueset ( https://hl7.eu/fhir/laboratory/0.1.0-ballot/StructureDefinition-specimen-additive-substance-eu-lab.html  ) with only 19 values might be too much limited.
      SNOMED CT
      1259913003    Heparin ammonium
      386961008    Aprotinin
      29725000    Heparin calcium
      21611007    Boric acid
      30531001    Calcium oxalate
      69519002    Edetic acid
      372628006    Edetate
      27763000    Hydrochloric acid
      414407009    Hirudin
      1256100007    Edetate dipotassium
      1256101006    Edetate tripotassium
      1256102004    Heparin lithium
      387418006    Edetate disodium
      412546005    Sodium citrate
      50045009    Heparin sodium
      6910009        Sodium fluoride
      50306007    Sodium tetraborate
      387168006    Mannitol
      115281000146102    Sodium formate

      More useful seems to be the valueset  https://terminology.hl7.org/ValueSet-v2-0371.html  (57 concepts), but that has no associated SNOMED codes so far, SNOMED should be asociated before usage.

      The bindings should be more open, set from preferred to example.

      Kind regards from Franziska van Wüllen and Martina Sender (mio42 GmbH, Germany)

      Attachments

        Activity

          People

            Unassigned Unassigned
            alexanderzautke Alexander Zautke
            Watchers:
            1 Start watching this issue

            Dates

              Created:
              Updated:
              Resolved: