    • Hide
      • keep Specimen.container.type as it is
      • add optional R5 extension for container device
      • put Specimen.container.additive 0..0

       

       

      Show
      keep Specimen.container.type as it is add optional R5 extension for container device put Specimen.container.additive 0..0    
    • Martina Sender / Rob Hausam : 9-1-0
    • Enhancement
    • Non-compatible

    Description

      Be aware:  FHIR R5 specimen resource will have

      • Container type as a device reference
      • an no more element "additive"  ("additive" will only be part of "processing")

      Germany (medical information object laboratory report) will more follow this concept, to avoid a later mapping of erased elements:

      • Container type as a device reference
        with device type code "434711009 |Specimen container (physical object)|  SNOMED Clinical Terms so far.
        And with device type category - maybe intensional valueset for specimen container type, we are still working on this.

      Kind regards from Martina Sender (mio42 GmbH, Germany)