      This is a copy and paste typo from the X-eHealth project model.

      Change the sentence as follow:

      "the specific details given - preferably as coded values - in the DiagnosticReport.extension:event-statusReason element."

      Show
      This is a copy and paste typo from the X-eHealth project model. Change the sentence as follow: "the specific details given - preferably as coded values - in the DiagnosticReport.extension:event-statusReason element."
    • Alexander Henket/Alexander Mense : 19-0-0
    • Correction
    • Non-substantive

    Description

      • the specific details given - preferably as coded values in the TestResultvalue.CodedResult element

      Where is "TestResultvalue.CodedResult" in DiagnosticReport?

      I would expect TestResultvalue.CodedResult to be identified as DiagnosticReport.result. ref to observation, where observation.valueCodeableConcept instead.

      If that is the correct assumption, then I thknk we should have discussion about this, since a cancelation reason is not a result = it should be sent in DiagnosticReport.result. ref to observation, where observation.dataAbsentReason is filled instead of the result. 