Uploaded image for project: 'FHIR Specification Feedback'
  1. FHIR Specification Feedback
  2. FHIR-41543

Update QI-Core QuestionnaireResponse profile to align with US Core 6.1.0

    XMLWordPrintableJSON

Details

    • Icon: Change Request Change Request
    • Resolution: Persuasive
    • Icon: Medium Medium
    • US QI Core (FHIR)
    • 5.0.0
    • Clinical Quality Information
    • QICore QuestionnaireResponse
    • QI-Core Profiles
    • Hide
      1. Import all elements in US Core 6.1.0 QuestionnaireResponse profile
      2. meta section – remove as this was part of US Core 5.0 and is not present in US Core 6.1.0
      3. QI-Core QuestionnaireResponse.subject – change reference to QICorePatient
      4. REMOVE QI-Core QuestionnaireResponse.encounter – present only in QI-Core
      5. REMOVE QI-Core QuestionnaireResponse.source – present only in QI-Core and highly unlikely to identify the provenance of the source of the responses – the response is completed by author and source of data is implied
      6. QI-Core QuestionnaireResponse.value[x] – US Core includes options valueDecimal, valueString, valueCoding. RETAIN QI-Core options valueDate, valueDateTime, valueDecimal, valueInteger, valueString, valueCoding, valueQuantity
      Show
      Import all elements in US Core 6.1.0 QuestionnaireResponse profile meta section – remove as this was part of US Core 5.0 and is not present in US Core 6.1.0 QI-Core QuestionnaireResponse.subject – change reference to QICorePatient REMOVE QI-Core QuestionnaireResponse.encounter – present only in QI-Core REMOVE QI-Core QuestionnaireResponse.source – present only in QI-Core and highly unlikely to identify the provenance of the source of the responses – the response is completed by author and source of data is implied QI-Core QuestionnaireResponse.value [x] – US Core includes options valueDecimal, valueString, valueCoding. RETAIN QI-Core options valueDate, valueDateTime, valueDecimal, valueInteger, valueString, valueCoding, valueQuantity
    • Floyd Eisenberg/Michelle Curie: 24-0-0
    • Enhancement
    • Non-compatible

    Description

      1. Import all elements in US Core 6.1.0 QuestionnaireResponse profile
      2. meta section – remove as this was part of US Core 5.0 and is not present in US Core 6.1.0
      3. QI-Core QuestionnaireResponse.subject – change reference to QICorePatient
      4. REMOVE QI-Core QuestionnaireResponse.encounter – present only in QI-Core
      5. REMOVE QI-Core QuestionnaireResponse.source – present only in QI-Core and highly unlikely to identify the provenance of the source of the responses – the response is completed by author and source of data is implied
      6. QI-Core QuestionnaireResponse.value[x] – US Core includes options valueDecimal, valueString, valueCoding. RETAIN QI-Core options valueDate, valueDateTime, valueDecimal, valueInteger, valueString, valueCoding, valueQuantity

      Attachments

        Activity

          People

            jen_seeman Jennifer Seeman
            feisenberg Floyd Eisenberg
            Watchers:
            3 Start watching this issue

            Dates

              Created:
              Updated:
              Resolved: