Uploaded image for project: 'FHIR Specification Feedback'
  1. FHIR Specification Feedback
  2. FHIR-41161

More Timing Guidance wrt time zone offset

    XMLWordPrintableJSON

Details

    • Icon: Change Request Change Request
    • Resolution: Persuasive
    • Icon: Highest Highest
    • US C-CDA on FHIR (FHIR)
    • 1.2.0-ballot
    • Cross-Group Projects
    • STU
    • Known Issues
    • Hide

      Agree to provide guidance.
      Question: what guidance
      1. Default to Universal time
      2. Infer time from location of document steward
      3*. DAR time; use extension for time without zone

      Show
      Agree to provide guidance. Question: what guidance 1. Default to Universal time 2. Infer time from location of document steward 3*. DAR time; use extension for time without zone
    • Jay Lyle/Michelle Currie: 10-0-0
    • Clarification
    • Non-substantive

    Description

      In FHIR dateTime if hours and minutes are specified, a time zone SHALL be populated.

      In C-CDA its a SHOULD, I have seem many C-CDA's in the wild where the timezone offset is missing when hours or minutes are present. Guidance on how to handle this should be provided

      Attachments

        Activity

          People

            Unassigned Unassigned
            GDolin Gay Dolin
            Watchers:
            5 Start watching this issue

            Dates

              Created:
              Updated:
              Resolved: