Details
-
Change Request
-
Resolution: Persuasive with Modification
-
Medium
-
FHIR Core (FHIR)
-
R5
-
Terminology Infrastructure
-
Terminologies
-
-
Carmela Couderc/Rob Hausam: 16-0-0
-
Enhancement
-
Non-compatible
-
R5
Description
Structure guidance for using Preferred binding strength similar to what is in the Example binding strength section where there are 3 bullets - code, Coding and CodeableConcept
Create 3 bullets
- code: Preferred binding SHALL NOT be used with the code datatype because the meaning is not predictable due to the inability to specify the system.url for a code that is not included in the bound ValueSet.
- Coding: The value SHOULD be from the specified value set, but another code and/or text can be used in its place.
- CodeableConcept: One of the Coding values SHOULD be from the specified value set, but another code and/or text can be used in its place.
Remove the sentence: If the datatype is CodeableConcept, then one of the Coding values SHOULD be from the specified value set, but another code and/or text can be used in its place.
Attachments
Issue Links
- relates to
-
FHIR-38964 Why there is no guidance for the code datatype?
-
- Resolved - No Change
-