Use reference to Device instead of codes in BodyStructure

XMLWordPrintableJSON

    • Icon: Change Request Change Request
    • Resolution: Persuasive with Modification
    • Icon: Medium Medium
    • FHIR Core (FHIR)
    • R5
    • Orders & Observations
    • BodyStructure
    • Hide

      Motion to:

      • change .distanceFromLandmark.device from CodeableConcept to   CodeableReference(Device) where the binding of the CodeableConcept is the same as Device.type.
      • change ".distanceFromLandmark.measurementDevice" to ".distanceFromLandmark.value"
      • change short display on .distanceFromLandmark.value (new name) from "Distance device measured" to "Distance from body landmark."

      We note that there is a concern with the naming of "distanceFromLandmark", but that will be addressed in a separate JIRA/discussion that addresses orientation as well.

      Show
      Motion to: change .distanceFromLandmark.device from CodeableConcept to   CodeableReference(Device) where the binding of the CodeableConcept is the same as Device.type. change ".distanceFromLandmark.measurementDevice" to ".distanceFromLandmark.value" change short display on .distanceFromLandmark.value (new name) from "Distance device measured" to "Distance from body landmark." We note that there is a concern with the naming of "distanceFromLandmark", but that will be addressed in a separate JIRA/discussion that addresses orientation as well.
    • JD Nolen / Yanick Gaudet : 7-0-4
    • Enhancement
    • Compatible, substantive
    • R5

      BodyStructure.includedStructure.bodyLandmarkOrientation.distanceFromLandmark.device should be a reference to Device not a CodeableConcept