Sampled data - additional special values

    XMLWordPrintableJSON

Details

    • Icon: Change Request Change Request
    • Resolution: Persuasive with Modification
    • Icon: Highest Highest
    • FHIR Core (FHIR)
    • R5
    • Modeling & Methodology
    • STU
    • Datatypes
    • 2.1.27.0.12
    • Hide

      Update SampledData to support a map as per what Grahame has committed to the CI build.  Will add language around not supporting numeric codes  or codes with spaces (though you could map such codes to plain alpha codes).

      Show
      Update SampledData to support a map as per what Grahame has committed to the CI build.  Will add language around not supporting numeric codes  or codes with spaces (though you could map such codes to plain alpha codes).
    • Bas van den Heuvel/Grahame Grieve: 17-0-0
    • Enhancement
    • Non-compatible
    • R5

    Description

      SampledData is defined as decimal values and "E", "L" and "U".

      We should rephrase this indicate that other special values can be added in the future and a mechanism parties can define proprietary codes (e.g. extension that defines them).

       