Correct improper panel modeling

    XMLWordPrintableJSON

Details

    • Icon: Change Request Change Request
    • Resolution: Persuasive
    • Icon: Highest Highest
    • At-Home In-Vitro Test Report (FHIR)
    • 1.0.0-ballot
    • Orders & Observations
    • Technical Guidance
    • 3.1.2
    • Hide

      Will update modeling to use hasMember (referencing Observation-at-home-in-vitro-test-result) for multiplex assay tests, rather than using component.

      High-level structure will be:

      • DiagnosticReport
        • Observation (panel/device)
          • hasMember.Observation1
          • hasMember.Observation2
      Show
      Will update modeling to use hasMember (referencing Observation-at-home-in-vitro-test-result) for multiplex assay tests, rather than using component. High-level structure will be: DiagnosticReport Observation (panel/device) hasMember.Observation1 hasMember.Observation2
    • Sarah Gaunt / Dan Rutz : 13 - 0 - 2
    • Correction
    • Compatible, substantive

    Description

      Multiple tests where each test can stand alone in its interpretation should be modeled using the hasMember relationship, not component.

      Existing Wording:

      Multiplex Assay tests that serve as a single test to diagnose infection caused by multiple viruses (e.g. CDC Flu SC2 Multiplex Assay for SARS-CoV-2, influenza A, and/or influenza B viruses), use multiple Observation.component elements to record each type of test.