Details
-
Change Request
-
Resolution: Persuasive with Modification
-
Medium
-
US Da Vinci CDex (FHIR)
-
2.0.0-ballot
-
Patient Care
-
Requesting Attachments [deprecated]
-
FHIR-38241 Definition of Attachment is limited
Description
The Task.input elements use the combination of a LOINC attachment code and service or starting date. This seems insufficient to indicate certain data requests. One may need a date range as a starting date may gather too much beyond that while only using LOINC attachments codes requires industry level pre-coordinated definitions, which at this stage would not seem realistic. How would one is looking for a particular lab test result (is its LOINC code or range of LOINC codes considered a LOINC attachment code?) was not provided that should be there in a particular time window?
Attachments
Issue Links
- duplicates
-
FHIR-38241 Definition of Attachment is limited
- Published
- is voted on by
-
BALLOT-39556 Negative - Hans Buitendijk : 2022-Sep-FHIR IG CDex R1 STU
- Balloted
-
BALLOT-40538 Negative - Doug Pratt : 2022-Sep-FHIR IG CDex R1 STU
- Balloted
-
BALLOT-40562 Negative - Frank Oemig - Cerner : 2022-Sep-FHIR IG CDex R1 STU
- Balloted
- relates to
-
FHIR-38241 Definition of Attachment is limited
- Published