Uploaded image for project: 'FHIR Specification Feedback'
  1. FHIR Specification Feedback
  2. FHIR-38124

Review and confirm all Must Support designations

    XMLWordPrintableJSON

Details

    • Icon: Change Request Change Request
    • Resolution: Persuasive
    • Icon: Medium Medium
    • US Da Vinci Patient Cost Transparency (PCT) (FHIR)
    • 0.1.0 [deprecated]
    • Financial Mgmt
    • PCT AEOB Bundle
      PCT Advanced EOB
      PCT Coverage
      PCT GFE Bundle
      PCT Good Faith Estimate Institutional
      PCT Good Faith Estimate Professional
      PCT Organization
      PCT Patient [deprecated]
      PCT Practitioner
    • Hide

      Will review all MS flags against the MS definition and remove any that are clearly not in alignment with the definition, but otherwise leave as is for phase 1. 

      Will implement must support recommendations in the attached spreadsheet. 

      Show
      Will review all MS flags against the MS definition and remove any that are clearly not in alignment with the definition, but otherwise leave as is for phase 1.  Will implement must support recommendations in the attached spreadsheet. 
    • Rick Geimer/Chris Cioffi: 8-0-0
    • Correction
    • Compatible, substantive

    Description

      Now that there is a definition for Must Support (FHIR-35202) all elements need to be evaluated to determine whether a must support flag is needed or not.

      Attachments

        Activity

          People

            rgeimer Rick Geimer
            corey_spears Corey Spears
            Watchers:
            2 Start watching this issue

            Dates

              Created:
              Updated: