Uploaded image for project: 'FHIR Specification Feedback'
  1. FHIR Specification Feedback
  2. FHIR-37833

Replace terminology slices with a base "preferred" binding and "additional binding" extensions.

    XMLWordPrintableJSON

Details

    • Icon: Change Request Change Request
    • Resolution: Persuasive
    • Icon: Medium Medium
    • International Patient Summary (FHIR)
    • 1.0.0
    • Patient Care
    • Profiles defined as part of the IPS Guide
    • Hide

      Slicing with terminologies have been replaced with valueSet binding and additional binding

      Show
      Slicing with terminologies have been replaced with valueSet binding and additional binding
    • John DAmore / Gay Dolin : 13-0-17
    • Enhancement
    • Compatible, substantive
    • current

    Description

      In the profiles, replace the slices that are being discriminated by the terminology bindings with a single base "preferred" binding for the element (from the full SNOMED CT release, where the use of SNOMED CT is appropriate) plus one or more "additional binding" extensions for the SNOMED CT IPS free set value sets (extensionally defined), where applicable, or value sets for that element from any other terminology or that are otherwise different from the base binding.  It should be necessary to include the "absent/unknown" codes only in the base "preferred" binding for the element.  We can also include a note saying that if one of the "additional bindings" is used, the expectation is that the "absent/unknown" codes will also be added to the value set definition and used along with it.

      Attachments

        Activity

          People

            Unassigned Unassigned
            rhausam Robert Hausam
            Watchers:
            2 Start watching this issue

            Dates

              Created:
              Updated:
              Resolved: