Uploaded image for project: 'FHIR Specification Feedback'
  1. FHIR Specification Feedback
  2. FHIR-36118

DTR SDC Questionnaire Profile Inappropriately Marks Elements As Must Support

    XMLWordPrintableJSON

Details

    • Icon: Change Request Change Request
    • Resolution: Not Persuasive with Modification
    • Icon: Medium Medium
    • US Da Vinci DTR (FHIR)
    • 1.1.0-ballot [deprecated]
    • Clinical Decision Support
    • DTR SDC Questionnaire [deprecated]
    • Artifact List
    • 5.6.1, 3.9
    • Hide

      Will retain Must Support flags, but agree to remove the sentence and direct to HRex definition of Must Support.

      Show
      Will retain Must Support flags, but agree to remove the sentence and direct to HRex definition of Must Support.
    • Bob Dieterle / Jeff Brown : 12-0-2
    • Correction
    • Compatible, substantive

    Description

      According to Section 3.9 - Must Support, the DTR implementation guide does not mark any elements with the Must Support flag in its profiles. And yet, the DTR SDC Questionnaire resource profile has several elements marked with the Must Support flag.

      Recommended change: Remove the Must Support flag from each element currently marked as such.