The PAS CommunicationRequest appears to be trying to fulfill the role of the PWK and HI segments on the 278 response to be used for submitting a solicited 275. However, there is not a field that is called out for the attachment control number that needs to be submitted on the 275.
If I had to venture a guess I would assume we should be using CommunicationRequest.identifier. If this is the case, this should be called out so it is known that this is the control number that needs to be utilized on a related 275 transaction. Otherwise, a field needs to be added to represent this concept.
Attachments
Issue Links
- has to be finished together with
-
FHIR-36114 PAS ClaimResponse and PAS Inquiry ClaimResponse use different CommunicationRequest profiles
- Resolved - No Change
- is voted on by
-
BALLOT-32453 Negative - Christopher Schaut : 2022-May-FHIR IG PAS R2 STU
- Withdrawn
-
BALLOT-32649 Negative - Daniel Rutz : 2022-May-FHIR IG PAS R2 STU
- Withdrawn
-
BALLOT-32672 Negative - Thanos Tsiolis : 2022-May-FHIR IG PAS R2 STU
- Withdrawn
-
BALLOT-32695 Negative - Chris Courville : 2022-May-FHIR IG PAS R2 STU
- Withdrawn
-
BALLOT-32764 Negative - Michael Clifton : 2022-May-FHIR IG PAS R2 STU
- Withdrawn
-
BALLOT-32787 Negative - David Sundaram-Stukel : 2022-May-FHIR IG PAS R2 STU
- Withdrawn
-
BALLOT-32833 Negative - Amit Popat : 2022-May-FHIR IG PAS R2 STU
- Withdrawn
-
BALLOT-32856 Negative - Cooper Thompson : 2022-May-FHIR IG PAS R2 STU
- Withdrawn
-
BALLOT-32879 Negative - Danielle Friend : 2022-May-FHIR IG PAS R2 STU
- Withdrawn
-
BALLOT-32718 Negative - Peter DeVault : 2022-May-FHIR IG PAS R2 STU
- Balloted
-
BALLOT-32741 Negative - Daniel Zhang : 2022-May-FHIR IG PAS R2 STU
- Balloted
-
BALLOT-32810 Negative - Isaac Vetter : 2022-May-FHIR IG PAS R2 STU
- Balloted
-
BALLOT-32902 Negative - Vassil Peytchev : 2022-May-FHIR IG PAS R2 STU
- Balloted
- relates to
-
FHIR-36114 PAS ClaimResponse and PAS Inquiry ClaimResponse use different CommunicationRequest profiles
- Resolved - No Change
- mentioned in
-
Page Loading...