Uploaded image for project: 'FHIR Specification Feedback'
  1. FHIR Specification Feedback
  2. FHIR-35989

ValueSet.description - align with and replace scope.focus

    XMLWordPrintableJSON

Details

    • Icon: Change Request Change Request
    • Resolution: Persuasive
    • Icon: Medium Medium
    • FHIR Core (FHIR)
    • R5
    • Terminology Infrastructure
    • ValueSet
    • Hide

      http://build.fhir.org/valueset-definitions.html#ValueSet.description

      Update comment text for valueset.description to this value: (note no change to the definition for valueset.description)

      Description should contain instructions for clinical or administrative use and interpretation - not a rendering of the value set as conveyed in the 'text' field of the resource itself. This item SHOULD be populated unless the information is available from context.

      A description SHOULD be provided unless the value set is a contained resource (e.g. a value set defined solely in the context of a profile).

       Remove focus from the scope complex element that was added in R5. 

      Show
      http://build.fhir.org/valueset-definitions.html#ValueSet.description Update comment text for valueset.description to this value: (note no change to the definition for valueset.description) Description should contain instructions for clinical or administrative use and interpretation - not a rendering of the value set as conveyed in the 'text' field of the resource itself. This item SHOULD be populated unless the information is available from context. A description SHOULD be provided unless the value set is a contained resource (e.g. a value set defined solely in the context of a profile).   Remove  focus  from the  scope  complex element that was added in R5.  
    • Reuben Daniels/John Snyder: 3-0-0
    • Clarification
    • Non-substantive
    • R5

    Description

      Discussed on the Feb 8, 2022 CPG/CQI VSD Profile call to address issues some have raised about the addition of scope as a first class element to ValueSet.

      http://build.fhir.org/valueset-definitions.html#ValueSet.description

      Update comment text for valueset.description to this value: (note no change to the definition for valueset.description)

      Description should contain instructions for clinical or administrative use and interpretation - not a rendering of the value set as conveyed in the 'text' field of the resource itself. This item SHOULD be populated unless the information is available from context.

      A description SHOULD be provided unless the value set is a contained resource (e.g. a value set defined solely in the context of a profile).

       Remove focus from the scope complex element that was added in R5. 

       

      Attachments

        Activity

          People

            jsnell Jessica Bota
            carmela_couderc Carmela A. Couderc
            Watchers:
            2 Start watching this issue

            Dates

              Created:
              Updated:
              Resolved: