Details
-
Change Request
-
Resolution: Persuasive with Modification
-
Medium
-
FHIR Core (FHIR)
-
R5
-
Modeling & Methodology
-
STU
-
MedicationRequest
-
-
Ron Shapiro/Rob Hausam: 3-0-0
-
Enhancement
-
Compatible, substantive
-
R5
Description
For PCA pumps, a lockout interval may be ordered. This is the minimal time between boluses initiated by the patient when pressing the button. If they press the button too soon, no medication is administered. How to represent the lockout interval?
Attachments
Issue Links
- is voted on by
-
BALLOT-43316 Negative - Vadim Peretokin : 2022-Sep-FHIR R5 STU
- Withdrawn
-
BALLOT-41889 Negative - Ricardo Quintano : 2022-Sep-FHIR R5 STU
- Closed
-
BALLOT-41913 Negative - Bas van den Heuvel : 2022-Sep-FHIR R5 STU
- Closed
-
BALLOT-42694 Negative - Javier Espina : 2022-Sep-FHIR R5 STU
- Closed
-
BALLOT-42796 Negative - Chris Melo : 2022-Sep-FHIR R5 STU
- Closed
-
BALLOT-42882 Negative - Bert Roos : 2022-Sep-FHIR R5 STU
- Closed
-
BALLOT-43199 Negative - Lisson Zhang : 2022-Sep-FHIR R5 STU
- Closed
-
BALLOT-43756 Negative - David Simons : 2022-Sep-FHIR R5 STU
- Closed
-
BALLOT-43898 Negative - Martin Rosner : 2022-Sep-FHIR R5 STU
- Closed
- mentioned in
-