Uploaded image for project: 'FHIR Specification Feedback'
  1. FHIR Specification Feedback
  2. FHIR-35815

Change QI Core Communication Resource MS items to Preferred Value Set bindings

    XMLWordPrintableJSON

Details

    • Icon: Change Request Change Request
    • Resolution: Persuasive
    • Icon: Medium Medium
    • US QI Core (FHIR)
    • 4.1.0 [deprecated]
    • Clinical Quality Information
    • QICore Communication
      QICore Communication Not Done
      QICore CommunicationRequest
    • Hide
      Show
      QICoreCommunication Communication.category uses http://hl7.org/fhir/ValueSet/communication-category ; change binding to “Preferred” Communication.statusReason uses http://hl7.org/fhir/ValueSet/communication-not-done-reason ; change binding to "Preferred" Communication.reasonCode uses http://hl7.org/fhir/ValueSet/clinical-findings ; change binding to "Preferred" QICoreCommunicationRequest CommunicationRequest.category uses http://hl7.org/fhir/ValueSet/communication-category ; change binding to “Preferred” QICoreCommunicationNotDone Communication.reasonCode uses http://hl7.org/fhir/ValueSet/clinical-findings ; change binding to "Preferred"
    •  Linda Michaelsen/Floyd Eisenberg: 17-0-0 approved
    • Enhancement
    • Non-compatible

    Description

      The following QI-Core profiles include Must Support elements with example binding to value sets. Change the bindings to Preferred

      Attachments

        Activity

          People

            bryn.rhodes Bryn Rhodes
            feisenberg Floyd Eisenberg
            Watchers:
            2 Start watching this issue

            Dates

              Created:
              Updated:
              Resolved: