Uploaded image for project: 'FHIR Specification Feedback'
  1. FHIR Specification Feedback
  2. FHIR-34920

On the AEOB profile, remove requirement for net; add requirement for adjudication

    XMLWordPrintableJSON

Details

    • Icon: Change Request Change Request
    • Resolution: Persuasive
    • Icon: Medium Medium
    • US Da Vinci Patient Cost Transparency (PCT) (FHIR)
    • 0.1.0 [deprecated]
    • Financial Mgmt
    • STU
    • (NA)
    • 7
    • Hide

      Remove constraints on davinci-pct-aeob ExplanationOfBenefit.item.net (Cardinality and MS).

      Add slices and invariants per FHIR-35260.

      Show
      Remove constraints on davinci-pct-aeob ExplanationOfBenefit.item.net (Cardinality and MS). Add slices and invariants per FHIR-35260 .
    • Rachel Foerster/Rick Geimer: 11-0-0
    • Correction
    • Non-compatible

    Description

      On the AEOB profile,

      remove Must Support from item.net and change the cardinality back to 0..1.

      add adjudication data elements, using C4BB Institutional Inpatient and C4BB Professional as patterns.

      Attachments

        Activity

          People

            Unassigned Unassigned
            taylorpatriciab Patricia Taylor
            Patricia Taylor
            Watchers:
            3 Start watching this issue

            Dates

              Created:
              Updated:
              Resolved: