Details
-
Change Request
-
Resolution: Persuasive with Modification
-
Highest
-
US Core (FHIR)
-
4.1.0 [deprecated]
-
Cross-Group Projects
-
STU
-
US Core DiagnosticReport Profile for Laboratory Results Reporting
-
10.107.1.3
-
-
Floyd Eisenberg/Eric Haas: 12-0-2
-
Correction
-
Compatible, substantive
Description
DiagnosticReport for Lab has constraint us-core-8 "effective[x] SHALL be present if the status is 'partial', 'preliminary', 'final', 'amended', 'corrected' or 'appended'". DiangosticReport.effective[x] has card. [1..1] in StructureDefinition
Similarly, AllergyIntolerance (and Condition) has constraint ait-1 "The clinicalStatus element has the following constraints: SHALL be present if verification status is not entered-in-error".
AllergyIntolerance.clinicalStatus has card. [0..1] in StructureDefinition.
Why these two elements have similar constraints but different cardinality?
Attachments
Issue Links
- is voted on by
-
BALLOT-26751 Negative - Yunwei Wang : 2022-Jan-FHIR US CORE R4.1 STU
- Withdrawn