Uploaded image for project: 'FHIR Specification Feedback'
  1. FHIR Specification Feedback
  2. FHIR-34482

Organization profile should mirror US Core telecom must support elements of system and value

    XMLWordPrintableJSON

Details

    • Icon: Change Request Change Request
    • Resolution: Persuasive with Modification
    • Icon: Medium Medium
    • US QI Core (FHIR)
    • 4.1.0 [deprecated]
    • Clinical Quality Information
    • QICore Organization
    • QI-Core Profiles
    • Hide

      Update QI-Core Organization to align with US Core 5.0.0:

      • Change cardinality of QI-Core Organization.telecom to 0..* and maintain datatype as ContactPoint (relaxes requirement)
      • Add Must Support for QI-Core Organization.telecom.system with cardinality 0..1 with datatype code and Required binding to ContactPointSystem

      Also Update QI-Core to be consistent with US Core 5.0.0 Organization by adding CLIA, noting that neither CLIA nor EIN are THO approved external identifier systems - see US Core tracker FHIR-36926, and EIN request UP-288
      Slices for identifier ΣI 0..* Identifiernote - should QI-Core require the following:
      MS identifier: All slices
      MS system Σ 0..1 uri
      MS value Σ 0..1 string
      MS identifier: NPI ΣI 0..1 Identifier
      MS system 1..1 uri
      NotMS identifier: CLIA 0..1 Identifier
      system 1..1 uri. binding Fixed Value: urn:oid:2.16.840.1.113883.4.7
      QI-CoreONLY
      MS identifier:ccn ΣI 0..1 Identifier
      system 1..1 uri
      value Σ 1..1 string
      MS identifier:ein ΣI 0..1 Identifier
      system 1..1 uri
      use ?!Σ 1..1 code Required binding to http://hl7.org/fhir/R4/valueset- identifier-use.html
      value Σ 1..1 string

      Show
      Update QI-Core Organization to align with US Core 5.0.0: Change cardinality of QI-Core Organization.telecom to 0..* and maintain datatype as ContactPoint (relaxes requirement) Add Must Support for QI-Core Organization.telecom.system with cardinality 0..1 with datatype code and Required binding to ContactPointSystem Also Update QI-Core to be consistent with US Core 5.0.0 Organization by adding CLIA, noting that neither CLIA nor EIN are THO approved external identifier systems - see US Core tracker FHIR-36926 , and EIN request UP-288 Slices for identifier ΣI 0..* Identifiernote - should QI-Core require the following: MS identifier: All slices MS system Σ 0..1 uri MS value Σ 0..1 string MS identifier: NPI ΣI 0..1 Identifier MS system 1..1 uri NotMS identifier: CLIA 0..1 Identifier system 1..1 uri. binding Fixed Value: urn:oid:2.16.840.1.113883.4.7 QI-CoreONLY MS identifier:ccn ΣI 0..1 Identifier system 1..1 uri value Σ 1..1 string MS identifier:ein ΣI 0..1 Identifier system 1..1 uri use ?!Σ 1..1 code Required binding to http://hl7.org/fhir/R4/valueset- identifier-use.html value Σ 1..1 string
    • Juliet Rubini/Abdullah Rafiqi: 15-0-0
    • Enhancement
    • Compatible, substantive

    Description

      Organization profile should mirror US Core telecom must support elements of system and value

      Attachments

        Activity

          People

            feisenberg Floyd Eisenberg
            jrubini Juliet K. Rubini
            Watchers:
            3 Start watching this issue

            Dates

              Created:
              Updated:
              Resolved: