Uploaded image for project: 'FHIR Specification Feedback'
  1. FHIR Specification Feedback
  2. FHIR-32795

Revise relatesTo.target[x] to BackboneElement

    XMLWordPrintableJSON

Details

    • Icon: Change Request Change Request
    • Resolution: Persuasive with Modification
    • Icon: High High
    • FHIR Core (FHIR)
    • R5
    • Clinical Decision Support
    • Citation
      EvidenceReport
    • Hide

      Update the relatesTo element to use the new RelatedArtifact type once changes from https://jira.hl7.org/browse/FHIR-32973 are applied.

      Show
      Update the relatesTo element to use the new RelatedArtifact type once changes from https://jira.hl7.org/browse/FHIR-32973 are applied.
    • Bryn Rhodes/Stan Rankins: 16-0-1
    • Enhancement
    • Non-compatible
    • R5

    Description

      target[x] 1..1 uri | Identifier | Reference | Attachment does not support common uses for which we want to express a canonical URL, and identifier, and a display.  Our previous efforts were functionally mis-using the Reference datatype where the canonical URL is not the FHIR Resource reference.

      Please change this to a target 0..1 Backbone element containing:

        url 0..1 uri

        identifier 0..1 Identifier

        display 0..1 markdown

        resource 0..1 Reference(Any)

        attachment 0..1 Attachment

      Attachments

        Activity

          People

            Unassigned Unassigned
            balper Brian S. Alper
            Watchers:
            2 Start watching this issue

            Dates

              Created:
              Updated:
              Resolved: