Uploaded image for project: 'FHIR Specification Feedback'
  1. FHIR Specification Feedback
  2. FHIR-30346

Example in allergy intolerance is incorrect SNOMED CT code

    XMLWordPrintableJSON

    Details

    • Type: Change Request
    • Status: Published (View Workflow)
    • Priority: Medium
    • Resolution: Persuasive

      Description

      Current:
      "code" : {
      "coding" : [

      { "system" : "http://snomed.info/sct", "code" : "387406002", "display" : "Sulfonamide (substance)" }

      ],
      "text" : "sulfonamide antibacterial"
      },

      Change to:
      "code" : {
      "coding" : [

      { "system" : "http://snomed.info/sct", "code" : "763875007", "display" : "Product containing sulfonamide (product)" }

      ],
      "text" : "Sulfonamide-containing product"
      },

      Reason:
      Medicinal product class concepts are to be represented using concepts drawn from the SNOMED CT Product hierarchy, not the substance hierarchy. That way implementers can use the NLM RxClass tool to identify the specific RxNorm drugs that fall within the class. This is not possible with SCT substances. The current value set is found here https://vsac.nlm.nih.gov/valueset/2.16.840.1.113762.1.4.1114.14/expansion/Latest