Mixed up references to intensional and extensional valueSets in Valueset-example-intensional.xml

    XMLWordPrintableJSON

Details

    • Icon: Technical Correction Technical Correction
    • Resolution: Persuasive
    • Icon: Medium Medium

    Description

      The code comments in https://www.hl7.org/fhir/valueset-example-intensional.xml.html incorrectly refer to intensional and extensional value set examples in reverse. References to intensional value sets should refer to extensional, and references to extensional value sets should refer to intensional.

      <!--     
          in extensional value sets, it's often done
          not to specify a locked date, or a version of the
          code system - we're saying, whatever are the right
          codes in the version you are using 
            -->
        <compose> 
          <include> 
            <system value="http://loinc.org"/> 
          <!--    
              instead of listing the codes (see the intensional example)
              we do something else: all codes in LOINC part LP43571-6
              
              Doing it like this means we can't change the displays (per the 
              intensional example). 
              
                  -->
      