Uploaded image for project: 'FHIR Specification Feedback'
  1. FHIR Specification Feedback
  2. FHIR-28493

Clarify reflex tests in LabServiceDefinition profile

    XMLWordPrintableJSON

Details

    • Icon: Change Request Change Request
    • Resolution: Persuasive
    • Icon: Medium Medium
    • Order Catalog (FHIR)
    • 0.1.0
    • Orders & Observations
    • Laboratory service Profile
    • 17.3.1
    • Hide

      Copy specification of reflex tests from the TORCH panel example to the LabServiceDefinition Profile

      Show
      Copy specification of reflex tests from the TORCH panel example to the LabServiceDefinition Profile
    • Lorraine Constable / Rob Hausam: 11-0-1
    • Clarification
    • Non-substantive

    Description

      This paragraph burried in the TORCH panel example should migrate to the specification of the LabServiceDefinition profile, as part of section 17.3.1.

      "Reflex tests are represented as sub-actions grouped in a logical group with behavior "any" meaning that any number of members of the group may be performed. Each sub-action is associated with a trigger of type "named-event" conveying the named event, which reflexes it."

      Attachments

        Activity

          People

            fmacary Francois Macary
            fmacary Francois Macary
            Watchers:
            1 Start watching this issue

            Dates

              Created:
              Updated:
              Resolved: