Uploaded image for project: 'FHIR Specification Feedback'
  1. FHIR Specification Feedback
  2. FHIR-28300

Measure Type valueset needs a concept map to the V3 codes

    XMLWordPrintableJSON

Details

    • Icon: Change Request Change Request
    • Resolution: Persuasive
    • Icon: Medium Medium

    Description

      The MeasureType code system and value set used from the base FHIR specification is newly defined within FHIR, it does not use the HL7 V3 code system and value set used in HQMF. This was a conscious decision to start with a clean slate, but there needs to be a mapping provided from the V3 code system and value set to the FHIR code system and value set:

      V3 Value Set: https://terminology.hl7.org/ValueSet-v3-ObservationMeasureType.html

      FHIR Value Set: http://hl7.org/fhir/R4/valueset-measure-type.html

       

      V3 -> FHIR

      COMPOSITE -> composite

      OUTCOME -> outcome

      STRUCTURE -> structure

      PROCESS -> process

       

       

      Attachments

        Activity

          People

            bryn.rhodes Bryn Rhodes
            bryn.rhodes Bryn Rhodes
            Watchers:
            3 Start watching this issue

            Dates

              Created:
              Updated:
              Resolved: