US Core Pulse Oximetry Profile: observation.value and component.value constraints are different

    XMLWordPrintableJSON

Details

    • Icon: Change Request Change Request
    • Resolution: Persuasive with Modification
    • Icon: Medium Medium
    • US Core (FHIR)
    • 3.1.0 [deprecated]
    • Cross-Group Projects
    • (NA)
    • Hide

      change component.valueQuantity.code and component.valueQuantity.unit
      min from 0 to 1 to be consistent with the valueQuantity constraints within US Core

      Show
      change component.valueQuantity.code and component.valueQuantity.unit min from 0 to 1 to be consistent with the valueQuantity constraints within US Core
    • Eric Haas / Floyd Eisenberg: 10-0-0
    • Correction
    • Non-compatible

    Description

      Why is US Core Pulse Oximetry Profile: observation.value and component.value sub elements constraints different? 

      Observation.value[x]:valueQuantity.value is 1..1

      Observation.value[x]:valueQuantity.unit is 1..1

      Component Flow Rate and Component Concentration

      Observation.component.value[x].value is 0..1

      Observation.component.value[x].unit is 0..1