Uploaded image for project: 'FHIR Specification Feedback'
  1. FHIR Specification Feedback
  2. FHIR-25648

Add meta.profile constraints to profiles and examples that cannot be reliably disambiguated by other constraints

    XMLWordPrintableJSON

Details

    • Icon: Change Request Change Request
    • Resolution: Persuasive
    • Icon: Medium Medium
    • International Patient Summary (FHIR)
    • Patient Care
    • Profiles defined as part of the IPS Guide
    • Hide

      proceed as pre-applied

      Show
      proceed as pre-applied
    • Rob Hausam/Alexander Zautke : 12-0-0
    • Enhancement
    • Compatible, substantive

    Description

      Add meta.profile constraints to the profiles that cannot be reliably disambiguated by other constraints - these profiles include the generic, lab, pathology and imaging Observation profiles (plus the generic and observer Device and laboratory and observation Organization profiles).  These additional meta.profile constraints are specified as optional (0..1) and mustSupport = false.  The intent is for them to not be required, but to be available whenever they are needed for reliable downstream disambiguation.  Also add the meta.profile constraints to the relevant example instances.

      Attachments

        Activity

          People

            Unassigned Unassigned
            rhausam Robert Hausam
            Watchers:
            1 Start watching this issue

            Dates

              Created:
              Updated:
              Resolved: