Uploaded image for project: 'FHIR Specification Feedback'
  1. FHIR Specification Feedback
  2. FHIR-25552

Proposal to add CodeableReference to .supportingInfo

    XMLWordPrintableJSON

Details

    • Icon: Change Request Change Request
    • Resolution: Persuasive
    • Icon: Medium Medium
    • FHIR Core (FHIR)
    • R4
    • Orders & Observations
    • ServiceRequest (Diagnostic/Procedure/ReferralRequest)
    • Hide

      See FHIR-25554 for the resolution of this issue. 

      It is in R5. Use the stadnrd pre-adoption mechanism ot use this in R4

      Show
      See FHIR-25554 for the resolution of this issue.  It is in R5. Use the stadnrd pre-adoption mechanism ot use this in R4
    • Hans Buitendijk / Rob Hausam : 15 - 0 - 0
    • Enhancement
    • Non-compatible
    • R5

    Description

      Proposal to add CodeableReference* to .supportingInfo to capture HL7 v2 OBR-13 codes and free text that often accompanies service requests. Theis would allow repeatinng codes, references and text.

      *see new R5 datatype : http://build.fhir.org/references.html#CodeableReference

      Need to discuss with vendors how free text here would be differentiated from the .note element if entered by the requester. And what additional guidance and example to provide. Have a related tracker to FHIR-I regarding the request pattern and what type of information should be present in note.

      Possible guidance to use contained references for very long text strings that are note really codeable and not appropriate for CodeableConcept.text.