Uploaded image for project: 'FHIR Specification Feedback'
  1. FHIR Specification Feedback
  2. FHIR-24547

CLIA regulations require slicing perfomer for labs - MCODE #130

    XMLWordPrintableJSON

Details

    • Icon: Change Request Change Request
    • Resolution: Persuasive with Modification
    • Icon: Medium Medium
    • US Minimal Common Oncology Data Elements (mCODE) (FHIR)
    • STU3
    • Clinical Interoperability Council
    • Profiles
    • TumorMarkerTest
    • Hide

      This issue falls under a general reconsideration of mCODE lab profiles, where it is proposed to drop the CBC and CMP laboratory profiles. The creation of the mCODE lab profiles was originally intended to accelerate the adoption detailed clinical models for labs in anticipation of CIMI laboratory profiles. It has become clear that if mCODE publishes lab profiles, and CIMI follows with its own lab profiles that are more or less different, mCODE will be guilty of creating a confusing situation with multiple laboratory profiles. Rather than risking that outcome, we propose eliminate this profile. In its place, we will list the LOINC codes of interest to mCODE, instruct implementers for the time being to follow US Core Laboratory Result profiles, and await publication of CIMI lab profiles.

      Proposed resolution: Persuasive with mod (delete profile)

      Show
      This issue falls under a general reconsideration of mCODE lab profiles, where it is proposed to drop the CBC and CMP laboratory profiles. The creation of the mCODE lab profiles was originally intended to accelerate the adoption detailed clinical models for labs in anticipation of CIMI laboratory profiles. It has become clear that if mCODE publishes lab profiles, and CIMI follows with its own lab profiles that are more or less different, mCODE will be guilty of creating a confusing situation with multiple laboratory profiles. Rather than risking that outcome, we propose eliminate this profile. In its place, we will list the LOINC codes of interest to mCODE, instruct implementers for the time being to follow US Core Laboratory Result profiles, and await publication of CIMI lab profiles. Proposed resolution: Persuasive with mod (delete profile)
    • Richard Esmond/Kurt Allen: 10-0-1
    • Enhancement
    • Compatible, substantive

    Description

      Comment:

      All of these are lab tests. Lab tests need (CLIA regulations) to have performing technologist, performing laboratory, and performing laboratory medical director. CIMI slices performer to do this. The CIMI slices are called ResponsibleObserver (lab tech), PerformingLaboratory, and PerformingOrganizationMedicalDirector.

      Summary:

      CLIA regulations require slicing perfomer for labs

      Attachments

        Activity

          People

            may_terry May Terry
            smatney Susan Matney (Inactive)
            Watchers:
            4 Start watching this issue

            Dates

              Created:
              Updated: