Uploaded image for project: 'FHIR Specification Feedback'
  1. FHIR Specification Feedback
  2. FHIR-23700

Value Set Extension: valueset-unclosed

    XMLWordPrintableJSON

Details

    • Icon: Change Request Change Request
    • Resolution: Persuasive with Modification
    • Icon: Medium Medium
    • FHIR Core (FHIR)
    • STU3
    • Terminology Infrastructure
    • ValueSet
    • Hide

      Change the following text:

      Marks that the expansion is incomplete, and values other than those listed may be valid. This may be used because post-coordinated codes are allowed, and no practical expansion can be produced.

       

      To

      Marks that the expansion is incomplete, and values other than those listed may be valid. This SHALL only be used when post-coordinated codes are allowed or codes with a grammar, and no practical expansion can be produced.

       

      Add the following to the comment for the extension:

      This extension is not used to communicate value sets that are limited for practical reasons. The offset and total elements of the expansion support that use case.

       

      Show
      Change the following text: Marks that the expansion is incomplete, and values other than those listed may be valid. This may be used because post-coordinated codes are allowed, and no practical expansion can be produced.   To Marks that the expansion is incomplete, and values other than those listed may be valid. This SHALL only be used when post-coordinated codes are allowed or codes with a grammar, and no practical expansion can be produced.   Add the following to the comment for the extension: This extension is not used to communicate value sets that are limited for practical reasons. The offset and total elements of the expansion support that use case.  
    • Grahame Grieve/Bryn Rhodes : 6-0-0
    • Clarification
    • Non-substantive
    • R5

    Description

      Value Set Extension valueset-unclosed satisfies an important requirement to identify a value set expansion that does not include all concepts that would be expected from evaluating the value set definition. An incomplete value set expansion used in an implementation could impact patient safety.

      On the August 12, 2019 Vocab Value Set Expansion call, two approaches were proposed (with a preference for #1) to ensure the implementer community is aware of the importance of this element and it is valued appropriately.

      1. Promote the valueset-unclosed extension to core. Requires: connectathon testing. (assumption: it should be simple for a terminology service to identify when input parameters have altered the expected expansion list)

      2a. Update section 4.9.8 Value Set Expansion https://www.hl7.org/fhir/valueset.html to require/strongly suggest that the valueset-unclosed extension be valued.

      2b. Update the extension description and constraints for https://www.hl7.org/fhir/extension-valueset-unclosed.html to reference a more common use case such as technical limitations (as seen in many FHIR value set expansions - "First 1000 codes" displayed message) Suggested text: Marks that the expansion is incomplete, and values other than those listed may be valid. This may be used when technical limitations prevent a full expansion, or when post-coordinated codes are allowed, and no practical expansion can be produced.

      Attachments

        Activity

          People

            GrahameGrieve Grahame Grieve
            carmela_couderc Carmela A. Couderc
            Watchers:
            2 Start watching this issue

            Dates

              Created:
              Updated:
              Resolved: