    Description

      ElementDefinition.binding.description:

      The value in the Description & Constraints column of the Content tab has this text:

      Human explanation of the value set

      This is not correct. The definition is: Describes the intended use of this particular set of codes.

      The binding description describes the binding, not the value set.

      Suggest changing the text to: Intended use of codes in the bound value set

      Found while researching #22794 during the July 29, 2019 VSE call.