Description for content indicates CQL code can be referenced. IG states otherwise:

    XMLWordPrintableJSON

Details

    • Icon: Change Request Change Request
    • Resolution: Persuasive
    • Icon: Medium Medium
    • US Quality Measures (FHIR)
    • STU3
    • Clinical Quality Information
    • StructureDefinition [deprecated]
    • Hide

      Agreed, update the description of the content element.

      Also, submit a tracker back to FHIR to clarify usage of the content element on a library.

      Show
      Agreed, update the description of the content element. Also, submit a tracker back to FHIR to clarify usage of the content element on a library.
    • Bryn Rhodes/Ben Hamlin: 16-0-0
    • Enhancement
    • Non-substantive

    Description

      Description for content indicates CQL code can be referenced. IG states otherwise:

      Conformance requirement 1:\\…
      CQFMLibraries SHALL specify content as a base-64-encoded string in content.data

      recommend rewording content description.

      Existing wording:

      Contents of the library, either embedded or referenced

      Proposed wording:

      Contents of the library, embedded as a base-64-encoded string