    Description

      Specification - Extended

      HL7 CDA® R2 IG: Reporting to Public Health Cancer Registries from Ambulatory Healthcare Providers, R1, DSTU Release 1.1 - US Realm

      Document Description

      extended per extended per TSC tracker 12458,14352, Jira TSC-14 and https://confluence.hl7.org/x/wpDGB

      Existing Wording

      Requiring both author device and author person is misrepresenting the purpose of the element. The author is the person or device that created the document. In the case of EMRs automatically generating a document from a patient encounter, this is the EMR software. If you're looking for information about who was the responsible person for the patient encounter, the information should be required as specific provider types within encompassingEncounter. SHALL contain exactly one [1..1] author (CONF:1169-33229) such that it SHALL contain exactly one [1..1] assignedAuthor (CONF:1169-33230). This assignedAuthor SHALL contain at least one [1..*] US Realm Address (AD.US.FIELDED) (V2) - Cancer IG Specific Constraints (identifier: urn:hl7ii:2.16.840.1.113883.10.13.17:2014-08-08) (CONF:1169-33231). This assignedAuthor SHALL contain exactly one [1..1] assignedPerson (CONF:1169-33233).

      Proposed Wording

      Remove these conformance statements, allowing inclusion of only the assignedAuthoringDevice. If required, add new conformance statements pointing to a more appropriate location for an individual contributor.

      Attachments

        Activity

          People

            Unassigned Unassigned
            john_stamm John Stamm
            Watchers:
            0 Start watching this issue

            Dates

              Created:
              Updated:
              Resolved: