Procedure Note has invalid cardinality on encompassingEncounter/location

    XMLWordPrintableJSON

Details

    • Icon: Technical Correction Technical Correction
    • Resolution: Persuasive
    • Icon: Medium Medium
    • C-CDA Templates Clinical Notes (CDA)
    • 2.1.0.6 [deprecated]
    • Structured Documents
    • Templates [deprecated]
    • Hide

      Reviewed on 7/14/2022 Example TF and agreed this is technical correction

      Show
      Reviewed on 7/14/2022 Example TF and agreed this is technical correction
    • Correction

    Description

      EncompassingEncounter elements may only have a single location

      Update conformance statement 30876 From:

      • This encompassingEncounter SHALL contain at least one [1..*] location (CONF:1198-30876).

      To:

      • This encompassingEncounter SHALL contain exactly one [1..1] location (CONF:1198-30876).