Details
-
Technical Correction
-
Resolution: Persuasive
-
Medium
-
C-CDA Templates Clinical Notes (CDA)
-
2.1.0.7 [deprecated]
-
Structured Documents
-
Figures and Examples [deprecated]
-
-
Correction
Description
The US Realm header template has the following constraints for documentationOf/serviceEvent/performer:
The performer, if present, MAY contain zero or one [0..1] functionCode (CONF:1198-16818).
a. The functionCode, if present, SHOULD contain zero or one [0..1] @code, which SHOULD be selected from ValueSet Care Team Member Function urn:oid:2.16.840.1.113762.1.4.1099.30
Figure 26 - includes performer/functionCode = "PP" from 2.16.840.1.113883.5.88, which is not part of this value set.
Recommend updating the example to instead reference "PCP" from 2.16.840.1.113883.5.88 which is part of the recommended value set.
Attachments
Issue Links
- relates to
-
CDA-1767 STU-1767 - functionCode
- Applied