    Description

      Specification - Extended

      HL7 CDA® R2 IG: C-CDA Templates for Clinical Notes DSTU Release 2.1 - US Realm

      Document Description

      extended per extended per TSC tracker 12437, again with 14128 and jira.hl7.org/browse/TSC-38

      Existing Wording

      In the Mental Stagus Organizer (V3) template (urn:hl7ii:2.16.840.1.113883.10.20.22.4.75:2015-08-01): a. The Organizer SHALL have at least one of code or effectiveTime (CONF:1198-32426). Why does this exist? We already know the organizer SHALL have a code because of CONF:1198-14378, so I can't see a circumstance in which this statement ever does anything.

      Proposed Wording

      [Remove conformance statement]