Description
The Smoking Status template *Smoking Status - Meaningful Use (V2) [observation, 2.16.840.1.113883.10.20.22.4.78, release 2014-06-09, open]* has an inconsistency in the constraint formation for the value elements.
Currently says:
SHALL contain exactly one [1..1] value with @xsi:type="CD" (CONF:1098-14810).
This value SHALL contain exactly one [1..1] @code, which SHALL be selected from ValueSet Smoking Status 2.16.840.1.113883.11.20.9.38 DYNAMIC (CONF:1098-14817).
If the patient's current smoking status is unknown, @code SHALL contain '266927001' (Unknown if ever smoked) from ValueSet Current Smoking Status ( 2.16.840.1.113883.11.20.9.38 STATIC 2014-09-01) (CONF:1098-31019).
Change to say:
SHALL contain exactly one [1..1] value with @xsi:type="CD" (CONF:1098-14810).
This value SHALL contain exactly one [1..1] @code, which SHALL be selected from ValueSet Smoking Status 2.16.840.1.113883.11.20.9.38 DYNAMIC (CONF:1098-14817).