Uploaded image for project: 'CDA Specification Feedback'
  1. CDA Specification Feedback
  2. CDA-1777

STU-1777 - Medication Supply Order statusCode value set

    XMLWordPrintableJSON

Details

    • Icon: Change Request Change Request
    • Resolution: Considered for Future Use
    • Icon: Highest Highest

    Description

      Specification - Extended

      HL7 CDA® R2 IG: C-CDA Templates for Clinical Notes DSTU Release 2.1 - US Realm

      Document Description

      extended per extended per TSC tracker 12437, again with 14128 and jira.hl7.org/browse/TSC-38

      Existing Wording

      The value set for statusCode for Medication Supply Order (v2) include several codes that are incompatible with the equivalent statusCodes in the FHIR US Core profile for MedicationRequest (http://hl7.org/fhir/STU3/valueset-medication-request-status.html). SHALL contain exactly one [1..1] statusCode (CONF:1098-7432). a. This statusCode SHALL contain exactly one [1..1] @code, which SHALL be selected from ValueSet ActStatus urn:oid:2.16.840.1.113883.1.11.15933 DYNAMIC (CONF:1098-32362). FHIR US Core profile value set: active on-hold cancelled completed entered-in-error stopped draft unknown

      Proposed Wording

      Recommend further constraining Medication Supply Order (v2). Consider excluding "new", "normal", "obsolete", and "aborted" out of use for the statusCode to align with FHIR equivalents.

      Attachments

        Activity

          People

            Unassigned Unassigned
            russell ott Russell Ott
            Watchers:
            0 Start watching this issue

            Dates

              Created:
              Updated:
              Resolved: