      Change conformance statements as follows:

      FROM:

      • This sdtc:dischargeDispositionCode SHOULD contain exactly [0..1] code, which SHOULD be selected from ValueSet 2.16.840.1.113883.3.88.12.80.33 NUBC UB-04 FL17-Patient Status (code system 2.16.840.1.113883.6.301.5) DYNAMIC or, if access to NUBC is unavailable, from CodeSystem 2.16.840.1.113883.12.112 HL7 Discharge Disposition (CONF:1198-32177).
      • This sdtc:dischargeDispositionCode SHOULD contain exactly [0..1] codeSystem, which SHOULD be either CodeSystem: NUBC 2.16.840.1.113883.6.301.5 OR CodeSystem: HL7 Discharge Disposition 2.16.840.1.113883.12.112 (CONF:1198-32377).

      TO:

      • This sdtc:dischargeDispositionCode SHOULD contain exactly [0..1] code, which SHOULD be selected from ValueSet 2.16.840.1.113883.3.88.12.80.33 NUBC UB-04 FL17-Patient Status (code system 2.16.840.1.113883.6.301.5) DYNAMIC
      Show
      Change conformance statements as follows: FROM: This sdtc:dischargeDispositionCode  SHOULD  contain exactly  [0..1]   code , which  SHOULD  be selected from ValueSet 2.16.840.1.113883.3.88.12.80.33 NUBC UB-04 FL17-Patient Status (code system 2.16.840.1.113883.6.301.5)  DYNAMIC  or, if access to NUBC is unavailable, from CodeSystem 2.16.840.1.113883.12.112 HL7 Discharge Disposition (CONF:1198-32177). This sdtc:dischargeDispositionCode  SHOULD  contain exactly  [0..1]   codeSystem , which  SHOULD  be either CodeSystem: NUBC 2.16.840.1.113883.6.301.5  OR  CodeSystem: HL7 Discharge Disposition 2.16.840.1.113883.12.112 (CONF:1198-32377). TO: This sdtc:dischargeDispositionCode  SHOULD  contain exactly  [0..1]   code , which  SHOULD  be selected from ValueSet 2.16.840.1.113883.3.88.12.80.33 NUBC UB-04 FL17-Patient Status (code system 2.16.840.1.113883.6.301.5)  DYNAMIC
    • Brett Marquard / John D'Amore: 14-0-0
    • Correction
    • Compatible, substantive
    • 2.1.0.7 [deprecated]

    Description

      Specification - Extended

      HL7 CDA® R2 IG: C-CDA Templates for Clinical Notes DSTU Release 2.1 - US Realm

      Document Description

      extended per extended per TSC tracker 12437, again with 14128 and jira.hl7.org/browse/TSC-38

      Existing Wording

      This sdtc:dischargeDispositionCode SHOULD contain exactly [0..1] codeSystem, which SHOULD be either CodeSystem: NUBC 2.16.840.1.113883.6.301.5 OR CodeSystem: HL7 Discharge Disposition 2.16.840.1.113883.12.112 (CONF:1198-32377).

      Proposed Wording

      The HL7 Discharge Disposition 2.16.840.1.113883.12.112 value set needs to be added to C-CDA R2.1 Release Package. THIS IS A VALUE SET WE HAVE FAILED TO FIND IN OUR EFFORTS TO ESTABLISH THE SOURCE OF TRUTH FOR ALL VALUE SETS USED BY C-CDA!